Section 1511 of the International Building Code, located 35 feet (10668 mm) or more above the <br />lowest level of fire department vehicle access, measured to the finished floor. <br />Exception: 1. Occupancies in Group F-2. <br />903.2.11.7 High -piled combustible storage. For any building with a clear height exceeding 12 <br />feet (4572 mm), see Chapter 32 to determine if those provisions apply. <br />903.2.11.8 Spray booths and rooms. New and existing spray booths and spraying rooms shall <br />be protected by an approved automatic fire -extinguishing system. <br />903.2.11.9 Buildings over 6,000 sq. ft. An automatic sprinkler system shall be installed <br />throughout all buildings with a building area 6,000 sq. ft. or greater and in all existing buildings <br />that are enlarged to be 6,000 sq. ft. or greater. <br />Exception: Open parking garages in compliance with Section 406.5 of the International Building <br />Code where all of the following conditions apply: <br />a. The structure is freestanding. <br />b. The structure does not contain any mixed uses, accessory uses, storage rooms, electrical <br />rooms, elevators or spaces used or occupied for anything other than motor vehicle parking. <br />C. The structure does not exceed 3 stories. <br />d. An approved fire apparatus access road is provided around the entire structure. <br />Amend Section 903.3.1.1.1. Exempt locations, to read as follows: <br />903.3.1.1.1 Exempt locations. When approved by the fire code official, automatic sprinklers <br />shall not be required in the following rooms or areas where such... (text unchanged)... because it <br />is damp, of fire -resistance -rated construction or contains electrical equipment. <br />1. Any room where the application of water, or flame and water, constitutes a serious life <br />or fire hazard. <br />2. Any room or space where sprinklers are considered undesirable because of the nature <br />of the contents, where approved by the fire code official. <br />3. Generator and transformer rooms, under the direct control of a public utility, separated <br />from the remainder of the building by walls and floor/ceiling or roof/ceiling assemblies <br />having a fire -resistance rating of not less than 2 hours. <br />4. {DELETED} <br />5. Elevator machine rooms, machinery spaces, and hoist ways, other than pits where such <br />sprinklers would not necessitate shunt trip requirements under any circumstances. <br />6. {DELETED} <br />Amend Section 903.3.1.2, NFPA 13R sprinkler systems, to read as follows: <br />903.3.1.2 NFPA 13R sprinkler systems. Automatic sprinkler systems in Group R occupancies <br />shall be permitted to be installed throughout in accordance with NFPA 13R where the Group R <br />occupancy meets all of the following conditions: <br />
The URL can be used to link to this page
Your browser does not support the video tag.