The alarm device required on the exterior of the building shall be a weatherproof <br />horn f strobe notification appliance with a minimum 75 candela strobe rating, <br />installed as close as practicable to the fire department connection. <br />Amend Section 905.2, Installation and standard, to read as follows: <br />905.2 Installation standard. Standpipe systems shall be installed in accordance <br />with this section and NFPA 14. Manual dry standpipe systems shall be supervised <br />with a minimum of 10 psig and a maximum of 40 psig air pressure with a high/low <br />alarm. <br />Amend Section 905.3, Buildings exceeding 10,000 soft. b ay dding Section 905.3.9 and <br />exception to read as follows: <br />905.3.9 Buildings exceeding 10.000 sq. ft. In buildings exceeding 10.000 square <br />feet in area per story and where any portion of the building's interior area is more <br />than 200 feet (60960 mm) of travel, vertically and horizontally, from the nearest <br />point of fire department vehicle access, Class 1 automatic wet or manual wet <br />standpipes shall be provided. <br />Exceptions: <br />1. Automatic dry, semi-automatic dry, and manual dry standpipes are <br />allowed as provided for in NFPA 14 where approved by the fire code official. <br />2. R-2 occupancies of four stories or less in height having no interior <br />corridors. <br />Amend Section 905.4, Location of Class I standpipe hose connections, by amending Items <br />1, 3, and 5, and adding Item 7 to read as follows: <br />905.4 Location of Class I standpipe hose connections. [Existing text <br />unchanged.) <br />1. In every required exit stairway, a hose connection shall be provided for each <br />story above and below grade plane. Hose connections shall be located at an <br />intermediate landing between stories, unless otherwise approved by the fire code <br />official. <br />Exception: [Unchanged <br />2. [Unchanged.] <br />3. In every exit passageway, at the entrance from the exit passageway to other <br />areas of a building. <br />Exception: Where floor areas adjacent to an exit passageway are reachable <br />from an exit stairway hose connection by a ... [remainder of text unchanged]. <br />15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.