public- and self -storage occupancies for interior corridors and interior common <br />areas. Visible notification appliances are not required within storage units. <br />Exception: [No change. <br />Amend Section 907.2.13, High-rise building, Exception 3, to read as follows: <br />907.2.13 High-rise building. [Existing text of section changed.] <br />Exceptions: [Existing Exceptions 1 and 2 unchanged.] <br />3. Open air portions of buildings with an occupancy in Group A-5 in accordance <br />with Section 303.1 of the International Building Code; however, this exception <br />does not apply to accessory uses including but not limited to sky boxes, <br />restaurants, and similarly enclosed areas. <br />Amend Section 907.4.2., Manual fire alarm boxes, by adding Section 907.4.2.7, Tzpe, to <br />read as follows: <br />907.4.2.7 Type. Manual alarm initiating devices shall be an approved double <br />action type. <br />Add Section 907.5.3, Occupant notification, to read as follows: <br />907.5.3 Occupant notification. Occupant notification in accordance with this <br />section and 907.5 shall be required for all new construction, or existing <br />construction complying with the International Building Code, for renovation to <br />existing buildings, tenant spaces, change in occupancy, replacement or <br />modification of the existing fire alarm system, or as required by the fire code <br />official for all buildings or spaces provided with an approved automatic sprinkler <br />system. <br />Amend Section 907.6.1, Wiring, b ay dding Section 907.6.1.1, Wiring installation, to read <br />asfollows: <br />907.6.1.1 Wiring installation. All fire alarm systems shall be installed in such <br />a manner that a failure of any single initiating device or single open in an initiating <br />circuit conductor will not interfere with the normal operation of other such <br />devices. All signaling line circuits (SLCI shall be installed in such a way that a <br />single open will not interfere with the operation of any addressable devices (Class <br />A). Outgoing and return SLC conductors shall be installed in accordance with <br />NFPA 72 requirements for Class A circuits and shall have a minimum of four feet <br />separation horizontal and one foot vertical between supply and return circuit <br />conductors. The initiating device circuit (IDCI from a signaling line circuit <br />Me <br />
The URL can be used to link to this page
Your browser does not support the video tag.