Laserfiche WebLink
Exceptions: <br />[Exceptions 1-7 unchanged.] <br />7. Buildings regulated under State Law and built in accordance with State <br />registered plans, including variances or waivers granted by the State, shall be <br />deemed to be in compliance with the requirements of Section 1009 and Chapter <br />11. <br />Amend Section 1010.2.5. Bolt locks, by amending Exceptions 3 and 4 as follows: <br />1010.2.5 Bolt locks. [Text unchanged.] <br />Exceptions: <br />[Exceptions 1 and 2 unchanged.] <br />3. Where a pair of doors serves an occupant load of less than 50 persons in a Group <br />B, F, M or S occupancy. (remainder unchanged[ <br />4. Where a pair of doors serves a Group A. B. F. M or S occupancy [remainder <br />unchangedl. <br />Amend Section 1020.2. Construction, by adding a new Exception 6 as follows: <br />1020.2. Construction. [Text unchanged.] <br />Exceptions: <br />[Exceptions 1-5 unchanged.] <br />6. In unsprinklered group B occupancies, corridor walls and ceilings need not be <br />of fire -resistive construction within a single tenant space when the space is <br />equipped with approved automatic smoke -detection within the corridor. The <br />actuation of any detector must activate self -annunciating alarms audible in all <br />areas within the corridor. Smoke detectors must be connected to an approved <br />automatic fire alarm system where such system is provided. <br />21 <br />