13 & 14 Building Code Updates (2)
City-of-Paris
>
City Council
>
Agenda Packets
>
2023
>
04 - APRIL
>
April 10
>
13 & 14 Building Code Updates (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/6/2023 12:20:03 PM
Creation date
4/6/2023 10:36:35 AM
Metadata
Fields
Template:
AGENDA
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Delete Section R110, CERTIFICATE OF OCCUPANCY CR110.1 through R110.5), in its <br />entirety. <br />Amend Section 113.4, Violation penalties, to read as follows: <br />113.4 Violation penalties. A person who shall violate a provision of this Code or <br />who fails to comply herewith or with any of the requirements hereof, or who shall <br />erect, construct, alter or repair, or who has erected, constructed, altered or <br />repaired a building or structure in violation of a detailed statement or plan <br />submitted and approved hereunder, or of a permit or certificate issued hereunder, <br />shall be guilty of a misdemeanor and, upon conviction, shall be fined in any sum <br />not to exceed two thousand dollars ($2.000.00). and each and every day's <br />continuance of any violation of the provisions of this Code shall constitute and be <br />deemed a separate offense. A violation of this code is a strict liability offense. <br />Table R301.2 U), CLIMATE AND GEOGRAPHIC DESIGN CRITERIA, fill in as follows: <br />GROUND <br />SNOW <br />LOAD <br />WIND DESIGN <br />SEISMIC <br />DESIGN <br />CATERGCIRY <br />SUBJECT TO DAPANGE FROM <br />WWINTER.. <br />DESIGN <br />TEMP, <br />ICE BARRIER <br />UNDER- <br />LAYMMENI° <br />FLOOD <br />H.APARDSg <br />AIiR, <br />FREEZING <br />INDEX' <br />MEAN <br />ANNUAL <br />TEMP" <br />SP'EED' <br />Ta'pa'graphi¢. <br />5P—i.IWm,d <br />Wmdh.-E <br />WNiatharing' <br />F,=Line <br />Termite" <br />(MPH) <br />Eh.e B' <br />Reginn' <br />D�hri.s'wn,e"° <br />I <br />D�ept'h' <br />S 1bf'Ft <br />No <br />No <br />No <br />A <br />PalCde ra to <br />6" <br />VR ryHea vy <br />22.' F <br />No <br />LocaI Cade <br />150 <br />E4.9� F <br />Delete remainder of table Manual [Design Criteria and footnote N <br />Amend Section R302.1, Exterior walls, b ay dding Exception 6 to read as follows: <br />R302.1 Exterior walls. [Text unchanged.] <br />Exceptions: [Exceptions 1-5 unchanged] <br />6. Open non-combustible carport structures may be constructed when also <br />approved within adopted ordinances. <br />Amend Section R303.3, Bathrooms, b ay dding the following text to the Exception: <br />R303.3. Bathrooms. [Text unchanged.] <br />Exception: [Existing text unchanged.] .. Spaces containing only a water closet <br />or water closet and a lavatory may be ventilated with an approved mechanical <br />recirculating fan or similar device designed to remove odors from the air. <br />Delete Section R313.2, One and Two Family Dwellings, and its subsection in their <br />entirety. <br />Amend Section R315.2.2, Alterations, repairs and additions, by adding the folloLA n <br />Exception 2: <br />27 <br />
The URL can be used to link to this page
Your browser does not support the video tag.