My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
13 & 14 Building Code Updates (2)
City-of-Paris
>
City Council
>
Agenda Packets
>
2023
>
04 - APRIL
>
April 10
>
13 & 14 Building Code Updates (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/6/2023 12:20:03 PM
Creation date
4/6/2023 10:36:35 AM
Metadata
Fields
Template:
AGENDA
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
R315.2.2 Alterations, repairs and additions. [Existing text unchanged.] <br />Exception: <br />1. [Unchanged.] <br />2. Installation, alteration or repairs of all electrically powered mechanical <br />systems or plumbing appliances. <br />Delete Section R322, Flood resistant construction, in its entirety. <br />Add Section R327.1.1, Adjacency to structural foundation, to read as follows: <br />R327.1.1 Adjacency to structural foundation. Depth of the swimming pool and <br />spa shall maintain a ratio of 1:1 from the nearest building foundation or footing of <br />a retaining wall. <br />Exception: A sealed engineered design drawing of the proposed new structure <br />shall be submitted for approval. <br />Amend Section R401.2, Requirements, b ay dding a new paragraph following the existing <br />paragraph to read as follows. <br />R401.2. Requirements. [Existing text unchanged.] <br />Every foundation and f or footing, or any size addition to an existing post -tension <br />foundation, regulated by this code shall be designed and sealed by a Texas - <br />registered engineer. <br />Amend Section R602.6.1, Drilling and notching of top plate, to read as follows: <br />R602.6.1 Drilling and notching of top plate. When piping or ductwork is placed <br />in or partly in an exterior wall or interior load-bearing wall, necessitating cutting, <br />drilling or notching of the top plate by more than 50 percent of its width, a <br />galvanized metal tie not less than 0.054 inch thick (1.37 mm) (16 Gal and 5 inches <br />(127 mm) wide shall be fastened across and to the plate at each side of the opening <br />with not less than eight 10d (0.148 inch diameter) having a minimum length of 1 <br />1/z inches (38 mm) at each side or equivalent. Fasteners will be offset to prevent <br />splitting of the top plate material. The metal tie must extend a minimum of 6 <br />inches past the opening. See figure R602.6.1. [Remainder unchanged. <br />Me <br />
The URL can be used to link to this page
Your browser does not support the video tag.