My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2023-018 - Amending Chapter 4 Article 4.02 Construction Codes and Standards
City-of-Paris
>
City Clerk
>
Ordinances
>
2023
>
2023-018 - Amending Chapter 4 Article 4.02 Construction Codes and Standards
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/14/2023 1:00:20 PM
Creation date
4/12/2023 3:30:04 PM
Metadata
Fields
Template:
CITY CLERK
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Amend Section 910.4.3.1 Makeup Air, to read as oilows; <br />910.4.3.1 Makeu. ain-MakeuL air o„1jenin4 shall be . rovided_withinIT6.feet. ",.1829 <br />mmof.the floor 1 veL Operation of makeup air.otaenin shall be automatic. The <br />minimum Lyross_area .ofmmakeu n air inlets shall be 8 sQ uare feet per ,1000 cubic <br />feet.,per minute 0.74 m2 per 0.4719._m3/s)..of smoke exhaust.. <br />Amend Section 912.2, Location, by adding Section 912.2..3 Hydrant distance to read as <br />ollows <br />912.2.3 H drant distance. An a:roved fire hydrant shall be located within 100 <br />feet of the fire department connection as the fire hose lays alp”,an unobstructed <br />path' <br />Amend Section 913.2.1, Protection ogre pump rooms & adding; Section 913.2.1.1, Fi <br />i�um�� room..access and Exce, tion to..read as.ollows: <br />913.2.1.1 Fire oump room access. When located on the ground level at an <br />exterior... -wall ... the fire pump room... shallITIT be provided with an exterior fire <br />department access door thatisnot less than 3 ft. in width and 6 ft. - 8.in. in height, <br />reardlessITof.a_ny interior doors that areroyjded. A ked box shall be rovided at <br />this door, as rewired by IFC Section 506.1. <br />Exception: When it is necessary to locate the fire pum,i room.on other levels or <br />not at an exterior wall the corridor leading,.to the fire pump room access from the <br />exter or..of the building shall...be,._provided with eq uivalent fire resistance as that <br />rewired for the lr uml. room or as a proved-hy the fire code official. Access keys <br />shall be iirovided in the key box as required by IFC Section 506..1. <br />Amend Section 1006.21 Egress based on occupant load and common path o ` e cess <br />travel distance to amend.Exception 3 to read as t lowsm <br />1006.2.1 Egress based on occupgnt load and common ath of a xress travel <br />distance.[Existing,text unchan ped. <br />Exce , tions: <br />3....MUnoccu pied rooftof: mechanical rooms and penthouses. are not reg, uir� ed to <br />coma �l?.with the commonath of egress travel distance measurement. <br />Amend Section 1009.8„ Two-Way...communication, bir addino the "ollowin Excet)tion 7; <br />1009.8 Two-wa communi tion. Existing. text unchanged. <br />20 <br />
The URL can be used to link to this page
Your browser does not support the video tag.