19 Public Safety Adoption of 2006 IFC
City-of-Paris
>
City Council
>
Agenda Packets
>
2001-2010
>
2009
>
05 May
>
05-11-2009
>
19 Public Safety Adoption of 2006 IFC
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/23/2012 8:24:24 AM
Creation date
5/8/2009 5:30:07 PM
Metadata
Fields
Template:
AGENDA
Item Number
19
AGENDA - Type
MISCELLANEOUS
Description
1994 Standard Fire Code
AGENDA - Date
5/11/2009
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2. Where buildings, balconies and deck are protected by an <br />approved automatic sprinkler system. <br />(29) Section 308.3.1.1 shall be amended to read as follows: <br />308.3.1.1 Liquefied-petroleum-gas-fueled cooking <br />devices. When permitted as listed in the exceptions of Section <br />308.3.1, LP-gas burners having an LP-gas container with a <br />water capacity greater than 32 fluid ounces [nominal 1 pound <br />(0.454 kg) LP-gas capacity] shall not be located on combustible <br />balconies or within 10 feet (3048 mm) of combustible <br />construction. <br />Exceptions: <br />1. One- and two-family dwellings may have containers with <br />a water capacity not greater than 5 gallons [nominal 21 <br />pound (9.08 kg) LP-gas capacity] with an aggregate <br />capacity not to exceed 1001bs (5 containers). <br />2. Other residential occupancies where buildings, balconies <br />and decks are protected by an approved automatic <br />sprinkler system, may have containers with a water <br />capacity not greater than 5 gallons [nominal 21 pound <br />(9.08 kg) LP-gas capacity] with an aggregate capacity not <br />to exceed 401bs (2 containers). <br />(30) Insert a new Section 401.3.4 that shall read as follows: <br />401.3.4 Fire Alarms and Nuisance Alarms. False alarms <br />shall not be given, signaled, or transmitted or caused or <br />permitted to be given, signaled, or transmitted in any <br />manner. <br />(31) Section 408.5,4 shall be amended to read as follows: <br />408.5.4 Drill frequency. Emergency evacuation drills shall be <br />conducted at least twelve times per year, four times per year on <br />each shift. <br />(32) Section 503.1.1 shall be amended to add the following language <br />to the first paragraph: <br />Except for single- or two-family residences, the 150 feet (150') <br />shall be measured along a ten foot (10') wide unobstructed <br />pathway around the external walls of the structure. The grade <br />12 <br />0 OUG18G <br />