B. Storm to Mainline Cross Connections <br />Two mainline to storm cross connections were not televised and ADS <br />recommends that these suspected cross connections be dyed water tested and <br />televised, and has designated rehabilitation code 491 to the defect type. This <br />rehabilitation code includes the cost to dye, televise, and point repair the defect. <br />Depending on the severity of the problem as determined through television <br />inspection, additional rehabilitation for the entire line segment may be necessary, <br />and this cost is not included. Sejzment 06-0170M - 06-0060M, PS-06 - A suspected storm/mainline smoke <br />defect was detected at a storm inlet directly in front of the Coca-Cola Bottling <br />Company of Paris (line length is 120 feet). During the smoke testing procedure, <br />smoke was observed from both sides of the intersection of 11`' NW St. and <br />Bonham St. The heaviest of the smoke was observed at the storm inlet. <br />Segment 10-0420T - 10-0410M, PS-10 - A suspected storm/mainline smoke <br />defect was detected approximately 356 linear feet downstream of 10-0420T, <br />which is a tee. The length of the line segment is 4401inear feet. <br />Another segment, segment 10-0045M -10-0035M, was identified during smoke <br />testing as a possible storm to mainline cross connection and was televised. After <br />subsequent analysis of this line segment, it was concluded that the segment would <br />be lined thereby eliminating the potential storm to mainline cross connection <br />defect. <br />C. Special Rehabilitation Codes <br />1. Special Line Rehabilitation Codes <br />During the course of the analysis, a need arouse for a grouping of minor <br />mainline defects that should be watched and eventually repaired, but <br />which were not as critical to the system condition as other, more severe <br />defects. Two rehabilitation codes were assigned to these defects: 40 and <br />ADS Environmental Services, Inc. <br />V-2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.