Laserfiche WebLink
E. Pre-hung units must have a fTame made of'4", material with a properly plowed jamb to rsceive 1 <br />or 1Ys d doors. A pre-hung unit musi be equipped with tho door panel, jamb, and all trim. <br />13.2. Methods <br />13.3. Exterior poois <br />A. Pre-hung exterior doois must be installed plumb and level. Door panel must not be trimmed or <br />manipulated in any fashion and must swing froe and easy. <br />B. When a panel is to be inserted into an existing frame, the door opening must be level and made <br />capable of holding the new door. Recommendad cleatsnce from the door edge to the jemb in <br />3/16". The door must not be trimmed or manipulated 'm any fashion and must swing free and <br />easy. <br />13.4. Interior poors <br />A. Pre-6ung units must be installed plumb and level to insure proper operation. Bottom of the door <br />may be cut off to allow proper ventilation and operation. <br />B. When a panel is to be inserted into an existing frame, the door opening must be level and made <br />capable of holding the new door. Recommended clearanee from the door to jamb is 3/16". The <br />panel must be cut off to allow proper ventilation and operation. <br />C. Bi-folding or lauvered bi-folding doors must be used where specified. They must have four <br />panels end have pulls attached to the outside two. T'hey must be installed plumb aad must fit <br />evenly and snug betwetn buttcd panels. <br />D. Pre-hung wooden doors vented a minimum of 100 square inches, top and bottom, must be used on <br />gas waten ceater closet door openings. Door must be installed plumb and levd for proper <br />operation. <br />13.5. Storm Doors <br />A. If mounting surface is rottcn or ia any manner deteriorated, it must be replaced. <br />B. Storm doors must be installed with screw fasteners and must be caulked and well fitted. <br />13.6. Scran Doors <br />A. Wooden screen doors must ba installed level and be closely fitud to insure protection from rodent <br />and insect infiitration. 1f the mounting surface is rotten or deteriorated, it must be replaced. <br />S. Aluminum screen doors must comply with the specifications for, storm doots. <br />13.7. Door Repair <br />A. Entrance doors must have 1'h", pair of door buus, weatherstrip tluuhold (mado of rolled vinyl <br />with aluminum channel backing). <br />B. Any ~ or missing pmts must be n,placal. <br />C. All make-shift door frames must be replaced (fill ia all holes at doors to be neat and permanent). <br />D. All doors must fit and work properly. <br />TDELCA - 80ME lnvestment Partnerships Program <br />Appendix A-04 - TMC Specificadons Page 15 of 24 Revixd 01 /Ol/2004 <br />226 <br />