Laserfiche WebLink
4. Rece.ssed wall mounted mirrored medicine cabinet at <br />5. L.evaWry wall, centered over lavatory. <br />6. Showedtub panel kit must be ABS plastic unit sealed with matching color silicone caulk <br />7. Chrorae shower curtain rod <br />New or rtplaced Dryer venting must be ducted through the exterior wall or to the exterior via <br />crawl space. All openings must be rodeat and weather proof. <br />H. New or replaced Washer Connections - must be recessed mount box in wall with DWV and water <br />faucets. Relocate or connect machine to operate properly es per plans. <br />New or replaced Hase Bibs - must be installed at locations on plans. Fxterior hose bibs must be <br />the frost-proof type. Instap frost-proof 6ose bib vacuum breaker on a(1 exterior hose bibs. <br />20.4. Gas Appliances <br />Wall Furnace - Must be U.L. listed wall fumace. It must include a11 connections, piping, and <br />fittings. Fumace must be thermostatically coaVolled, high efficiency, forced sir, sutomatic fan <br />control unit. $TU output and number of unita tnust be determined in the individual Specifications. <br />Unit must have gas shutoff located adjacent to the unit. The unit must be installed by a licensed <br />HVAC contractor. <br />B. Install new water heater to be 30 gallon high efficiency, gas find automa6c tank type heater <br />located ss per plans. Unit must include all new venting and conneccions. Gas outlet and cut off <br />must be located at front of water heater c[oset. Fresh air inlets are required at top and bottom to <br />allow combustion air to vent from t6e outside. Installation must be according to SBCC. <br />20.5. Pipiag <br />A. New or replaced Drain, waste, and vent lines must be standard weight galvanized stetl pipe with <br />cast iron drainage Sttings, or standard weight cast iron soil pipe and Sttings or schedule 40 <br />polyvinyl chloride pipe and fittings. All piping passing through the roof must be properly flashed. <br />Must have clean-out located at exterior of house. <br />B. New or replaced Water lines must be type "L" copper, located inside wall cavities. After <br />installation they must be pt+essure testod with 125 psi for 30 minutes prior to coverage. A <br />dielxtric fitting is required between piping of diesimilar metals. A(1 water tines above ground and <br />not inside an insulatod wall cavity or ceiling/attic space will be $+eeze protecW with'/i', <br />fiberglass insulation or'/:" armorflox, sealed at sll joints. <br />C. All existing gas piping is to be tested with 61b. mercury coEwnn. My lealcs will be reported <br />immediatelv to Contract Administrator. <br />D. All year service lines (water, sewer and ges) must have a minimum of 12b', of ground covcr. <br />21.0 Electtical <br />21.1. General Specifications <br />A. All new electrical installations must conform with the National Elxtrical Code. <br />TDHCA - HOME Investment Parhâ–ºerships Program <br />Appendix A-04 - TMC SpecificaNons Page 22 of 24 Revisod 01101/2004 <br />233 <br />