B. Pians must be considered as recommended layout, however, the National Electrical Code must be <br />the rule in a!1 instances. <br />C. New or replaced mast, meter loop, and breaker penel as per plans and work-write ups. <br />D. AU fixtures must be U.L. approved. <br />E. All wiring must be fished in wall cavities. Any surface roounted wiring must be in smooth EMT <br />conduit or wire mold securoly mounted. <br />21.2. Materials <br />21.3. Fixtures <br />A. Smoke and CO Detector For all new construction and rehabilitation of muld-familvgroperties: <br />110 volt U.L. listed amoke alarm unit installod according to State of Texas pcoperty code, <br />Southern Building Code and manufacturees recommendation at location(s) apecified on pmject <br />specifications. Also at least one carbon monoxide detector must be installed ef natural gas or other <br />combustible is used as fuel source. <br />B. Smoke and CO Detector-For RehabilitaNon of ovmer occwied housing: battery operated smoke <br />detectors and at least one carbon monoxide detector must be installed to provide adoquate <br />coverage for the entire household. <br />C. Bathroom ceiling heater must be forced fan unit Instalt as pcr plans and manufacturer's <br />recommendationa. <br />D. Bath Exhaust Pan must be U.L. approved and installed to meet all applicable local codes. <br />B. Newly installed Range Hood must be U.L. listed and vonted ttuough the roof. <br />F. Service Entrance must be a minimum 100 amp, l 20/240v service as per plans. <br />G. GFCI's will be installed at any outlet that is within six feet of a water sout+ce measuted at the <br />shortest distance, sueh devices will be properly grounded and tested for proper function. <br />22.0 MieceWneoua <br />22.1. Extecmination <br />A. Property must have one year policy with initial and throe (3) quarterly return ttratments for ants, <br />roaches, silverfiah and rodents if required. <br />B. Property must have a vne time treatment for termite controt. Both extomunarions must be <br />perfornied by a licensad and bonded company and must have a one year written warranty or <br />guarantee delivet+ed to the homeowner through the Contract Administrator. A one time fee for <br />matment must be made for the initial treatments end the three quarterly treakments, if required. <br />23.0 Attic Acccss <br />23.1. Must be located as per plans. Dimensions must be listed on plana. Scuule hok cover must be 5/8b', <br />plywood with a smooth finish. Trim must be H trim with mitered joints. Paint to match other trim in <br />house. Cover must have insulation batt out to fit on top of it. <br />TDHCA - HOME Investmmt Parmerships Program <br />Appendix A-04 - TMC Specifications Page 23 of 24 Revised 01/01/2004 <br />` <br />