My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1612 ORD AMENDING ORDINANCE NO 1274 THE ELECTRICAL ORDINANCE
City-of-Paris
>
City Clerk
>
Ordinances
>
1889-2010
>
1941-1999
>
1960-1969
>
1963
>
1612 ORD AMENDING ORDINANCE NO 1274 THE ELECTRICAL ORDINANCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/27/2017 11:22:47 AM
Creation date
6/22/2012 2:41:21 PM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - Date
1/14/1963
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ORDINANCE NO. 1612 . <br />AN ORDINANCE AMENI?ING ORDINANCE NO. 1274, THE ELEC TRICAL <br />OR.L?INANCE, PASSEI? BY THE GITY COUNGIL, ON THE lOTH I?AY OF <br />NOVEMBER, 1952, AI?OPTItVG THE 1962 NA TIONAL ELEC TRICAL C OI?E, <br />WITH CERTAIN LIMITATIONS ANI? EXCEPTIONS; PROVII?IlVG FOR EXCEP- <br />TIONS T O 210-22, SUBSEC TION (b), WITH REFERENGE TO RECEPTACLE <br />OUTLETS, EXCEPTING FROM THE 1962 COI?E THE FOLLOWING: SER- <br />VICE ENTRANCE CABLES; ALL SERVICE ENTRANCE CABLES FROM THE <br />METER SOCKET TO THE PANEL SHALL BE INSTALLEI? 1N EITHER OF <br />THE FOLLOWING WAYS: (1) ALL I?ISCONNECTS TO BE LOCATEI? BACK <br />OF THE NIETER ANI? INSII?E OF THE WALL W ITH C ONI?UIT NIPPLE, <br />(2) EACH SERVICE ENTRANCE SHALL BE PLACED IN C ONI?UIT FROM <br />THE ME TER SOC KE T TO THE PANEL W ITH NO MAIN I?15C ONNEC T A T <br />THE METER, (3) ALL SERVICE CABLE FROM THE METER SOCKET TO <br />THE MAIN I?ISC ONNEC T SHALL BE ENC LOSED IN C ONI?UIT; THE MIlVIMUM <br />SIZE I?I'"CONNECT SHALL BE 50 AMP; SERVICE PANEL BREAKERS - <br />BREAKERS KNOWN AS PIGGY-BACK, TANI?UMS, TWINS, THINS, AND ANY <br />OTHER OF THI,S TYPE BREAKER, ARE HEREBY PRO:HIBITEI? ON ANY <br />NEW OR REPAIR IlVSTALLA TIONS; PROVIDING THA T ALL TR.AILER <br />HOUSES SHALL HAVE A I?RNEN GROUND OR WATER PIPE GROUNI? <br />C ONNECTEI? TO THE TRAILER HOUSE AND HAVE POLARIZEI? PLUG <br />1NS; THAT SEC TION 9 QF ORDINANCE NO. 1274 BE AMENI?EI? TO PRO- <br />VIi?E FOR ANNUAL LICENSE FEE FOR AN ELEC TRICAL C ONTRAC TOR <br />OF $100.00 FOR THE FIR.ST YEARS LIGENSE ANI? A FEE OF $25.00 FOR <br />EAGH RENEWAL FOR EACH YEAR THEREAFTER; PROVII?ING FOR A <br />PE NALTY; ANI? PR OVII?IlVG FOR AN EFFEC TIVE I?A TE. <br />BE IT ORI?A 1NEI? BY THE C ITY C OUNC LL.. OF THE C ITY OF PA RTS: <br />That Ordinance No. 1274, passed by the City Council on the lOth day of <br />November, 1952, be, and the same is hereby amended as follows: <br />Section 1. That the 1962 National Electrical Code, governing installa- <br />tions and wiring of electric installations, together with all subsequent <br />amendments thereto, are hereby adopted by the City of Paris, Texas, with <br />the following limita.tions and exceptions: <br />(1) Section 210-22, Subsection (b) of said National Electrical Code <br />is hereby amended to read as follows: <br />That on all dwelling type occupancies, in every kitchen, dining <br />room, breakfast room, living room, parlor, library, den, sun- <br />room, recreation room, and bedroom, receptacle outlets shall <br />be insta.lled so that no point along the floor line in any useable <br />wall space is more than 6 feet, measured horizontally from an <br />outlet in that space, including any useable wall space 2 feet <br />wide or greater and the wall space occupied by sliding panels <br />in exterior walls. The receptacle outlets shall, insofar as <br />practicable, be spaced equal distances apart. Receptacle out- <br />lets in floors shall not be counted as part of the required num- <br />ber of receptacle outlets unless located close to the wall. <br />(2)Service Entrance Cables: All service entrance cables from <br />the meter socket to the panel shallhe installed in either of <br />the following three ways: <br />(a) The disconnect shall be located back of the meter in <br />inside of wall with conduit nipple. <br />(b) If the service eritrance cable is placed in conduit from <br />the meter socket to the panel, no main disconnect shall be <br />required at the meter, <br />(c) Any service cable from the meter socket to the main <br />disconnect shall be enclosed in conduit. <br />
The URL can be used to link to this page
Your browser does not support the video tag.