My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1508 ORD AMENDING ORDINANCE NO 1074 AND ORDINANCE NO 1202
City-of-Paris
>
City Clerk
>
Ordinances
>
1889-2010
>
1941-1999
>
1960-1969
>
1960
>
1508 ORD AMENDING ORDINANCE NO 1074 AND ORDINANCE NO 1202
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/27/2017 1:37:52 PM
Creation date
6/26/2012 11:11:38 AM
Metadata
Fields
Template:
CITY CLERK
CITY CLERK - Date
3/14/1960
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Section 29. In buildings more tha.n two stories high, the pipes and <br />fitti.ngs required by Section 26, 27, and 28 of this Ordinance to be of <br />standard cast iron, ahall be extra heavy cast iron for the first two <br />stories, and in buildinga of more than three stories in height, aame must <br />be of extra heavy cast iron for every atory except the last two atories, <br />standard cast iron being allowed in the last two stories. <br />Section 30. The following is the permissible waste schedule under <br />this OrdinanceY <br />Inches <br />1 1/2 <br />2 <br />3 <br />4 <br />5 <br />6 <br />Closets ...o..... <br />1-10 <br />11-35 <br />36-50 <br />Sand Traps,o.o.. <br />1-10 <br />11-35 <br />36-50 <br />Catch Basins... o. <br />6-20 <br />21-35 <br />36-50 <br />Slop Sinkso p <br />1 <br />2-5 <br />1 I-40 <br />41-7 0 <br />71-100 <br />Bath Tubs..Q,.... <br />1 <br />2 <br />5-10 <br />11-100 <br />101-175 <br />176-250 <br />Seitz Tubs...... 0 <br />1 <br />2-4 <br />5-10 <br />11-100 <br />101-175 <br />176-250 <br />Kitchen Sinks..... <br />1 <br />2-4 <br />5-10 <br />11-100 <br />101-175 <br />176-250 <br />Urinals..,,.,..... <br />1 <br />2-4 <br />5-10 <br />11-100 <br />101-175 <br />I76-250 <br />Wash Trays.,,... <br />1-3 <br />4-7 <br />7-10 <br />11-100 <br />101-175 <br />176-250 <br />Pantry Sinks...... <br />1-3 <br />4-8 <br />9-20 <br />21-100 <br />101-175 <br />176-250 <br />Wash Basins.o..,. <br />1-3 <br />4-8 <br />9-20 <br />21-100 <br />101-175 <br />176-250 <br />Drinking Fountains <br />2 <br />3-8 <br />9-20 <br />21-100 <br />101-175 <br />176-250 <br />Section 31. The following is the permissible vent schedule under <br />this Ordinance: <br />Inches <br />1 1/4 1 1/2 <br />2 <br />3 <br />4 <br />5 <br />6 <br />4 <br />5-10 <br />11-20 <br />21-35 <br />36-50 <br />Sand Traps.,.,.. <br />4 <br />5-10 <br />11-20 <br />21-35 <br />36-50 <br />CAtch basins., o.. <br />4 <br />5-10 <br />11-20 <br />21-35 <br />36-50 <br />Slop Sinkso...o.., <br />1 <br />2-4 <br />5-10 <br />11-20 <br />21-35 <br />36-50 <br />Bath Tubs, .~.o... <br />1 2 <br />3-8 <br />9-20 <br />21-40 <br />41-70 <br />71-100 <br />Seitz Tubs <br />2 <br />3-8 <br />9-20 <br />21-40 <br />41-70 <br />71-100 <br />Urinals,.e....... <br />2 <br />3-8 <br />9-20 <br />21-40 <br />41-70 <br />71-100 <br />Wash Trays...... <br />1-3 <br />4-8 <br />9-20 <br />21-40 <br />41-70 <br />71-100 <br />Wash Basins,.... <br />1 1-4 <br />5-8 <br />9-20 <br />21-40 <br />41-70 <br />71-100 <br />Pantry Sinks. <br />1-4 <br />5-8 <br />9-20 <br />21-40 <br />41-70 <br />71-100 <br />Drinking Fountain <br />1-4 <br />5-8 <br />9-20 <br />Kitchen Sinks..... <br />2 <br />3-8 <br />9-20 <br />21-40 <br />41-70 <br />71-100 <br />Section 32. Each building, house or outhouse must be provided with <br />at least one faur-inch waste or vent stack, and for every branch of 30 feet <br />or more in length within the same building aame shall extend full size and <br />bore through roof or brought back full size to main stack. Where conditions <br />require a five or six inch waste or dra n pipe within the building, then there <br />shall be a five or six inch vent carried out through roof, and for every <br />branch of 30 feet or more within the building in length sarre sha.ll extend <br />full size through roof or be returned full size to main stack. <br />Section 33. Where revent pipes are connected into main atack it <br />shall be at a point of at least one foat above highest fixture. <br />Section 34„ No continuous revent shall be placed more tha,n thirty-six <br />(36) inches from the trap it serves, and the center of outlet between the <br />waste and vent shall not bE set below the water seal of the trap. <br />