CITY OF PARIS COMPREHENSIVE PLAN
<br />Appendix C- Zoning and Subdivision Ordinance Text Amendments
<br />reasons for any omissions.
<br />Site Plans shall be prepared by a rejistered professional engineer, architect, land surveyor or
<br />landscape architect at a scale of 1 inch equals 20 feet, on standard 24" x 36" sheets. Items
<br />required for submission include:
<br />A. Name of the project, address, boundaries, date, north arrow and scale of the plan.
<br />B. Name and address of the owner of record, developer, and seal of the engineer, architect or
<br />landscape architect.
<br />C. Name and address of all owners of record of abutting parcels.
<br />D. All existing lot lines, easements, and rights-of-way. Include area in acres or square feet,
<br />abutting land uses and structures.
<br />E. The location and use of all existing and proposed structures within the development.
<br />Include all dimensions of height and floor area, and show all exterior entrances and all
<br />anticipated future additions and alterations. For developments in the Central Business
<br />District (CBD), indicate design details to make new construction compatible with
<br />existing structures.
<br />F. The location of all present and proposed public and private ways, parking areas,
<br />driveways, sidewalks, ramps, curbs and fences. Location, type, and screening details for
<br />all waste disposal containers shall also be shown.
<br />G. The Zoning Administrator may require location, height, intensity, and bulb type (e.g.,
<br />fluorescent, sodium incandescent) of all external lighting fixtures. The direction of
<br />illumination and methods to eliminate glare onto adjoining properties must also be
<br />shown.
<br />H. The location, height, size, materials, and design of all proposed signage.
<br />I. The Zoning Administrator may require a landscape plan showing all existing open space,
<br />trees, forest cover and water sources, and all proposed changes to these features including
<br />size and type of plant material. Water sources will include ponds, lakes, brooks, streams,
<br />wetlands, flood plains, and drainage retention areas.
<br />J. The location of all present and proposed utility systems including:
<br />(1) sewerage system;
<br />(2) water supply system;
<br />(3) telephone, cable and electrical systems; and
<br />(4) storm drainage system including existing and proposed drain lines, culverts, catch basins,
<br />headwalls, endwalls, hydrants, manholes, and drainage swells.
<br />K. Plans to prevent the pollution of surface or groundwater, erosion of soil both during and
<br />after construction, excessive run-off, excessive raising or lowering of the water table, and