Laserfiche WebLink
Paris Santa ]:e-Frisco Depot Rehabilitation © KEYSTONE ARCHITECTS <br /> July 10, 2001 <br /> <br />SECTION 08610 WOOD WINDOWS <br /> <br />SECTION 08610: WOOD WINDOWS <br /> <br />PART 1 - GENERAL <br /> <br /> 1.01 DESCRIPTION OF WORK: Rehabilitation of existing historic wood windows and in- <br /> kind replacement of missing historic wood windows with new replica wood windows. <br /> Extent of window repair and replacement is indicated on the Drawings. <br /> <br /> A. Existing Windows Restoration and Repair: All existing windows exhibiting Class I or <br /> Class II repairable damage, as per Section 06700 - Wood Restoration, extent and location <br /> as shown on Drawings, shall be restored as specified herein. <br /> <br /> B. New Replica Windows: All missing original windows, as well as all existing windows <br /> exhibiting damage beyond Class II repairable damage, as per Section 06700 - Wood <br /> Restoration, extent and location as shown on Drawings, shall be replaced with new in-kind <br /> replica windows as specified herein. Extent and location as shown on drawings. <br /> <br /> C. Wood Trim: New and RestoredExisting exterior and interior wood triras as specified <br /> in SECTION 06700 - WOOD RESTORATION. Replacement in-kind of any <br /> missing trims or trims damaged beyond Class II repairable damage. Refer to Section <br /> 06200 Finish Carpentry for interior and exterior wood trim not specified as integral <br /> components of window units (casings, moldings, stools, aprons, mullion covers <br /> and similar components). <br /> <br /> D. Glazing: Provide in-kind glazing to match existing, or as specified here-in, or as shown on <br /> Drawings. <br /> <br /> E. All existing original windows to be restored are to be returned to original working <br /> condition. <br /> <br />1.02 INCORPORATED DOCUMENTS: <br /> <br /> A. GENERAL CONDITIONS, DIVISIONS 00 and 01, and SECTIONS 06200 Wood <br /> Restoration and 07900 Sealants apply to all work of this section. <br /> <br /> B. Published specifications, standards, tests, or recommended methods of trade, industry, or <br /> governmental organizations apply to work of this section where cited by abbreviations <br /> not~l below: <br /> <br /> 1. Federal Specifications (FS). <br /> 2. National Woodwork Manufacturers Association (NWMA). <br /> 3. Secretary of the Interior Standards for Rehabilitation. <br /> 4. Stained Glass Indust~'y Standards <br /> 5. National Park Service Technical Bulletins <br /> <br /> Section 08610 <br /> Page 1-5 <br /> <br /> <br />