My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
06-J Cox Field Water Main
City-of-Paris
>
City Council
>
Agenda Packets
>
2001-2010
>
2001
>
12 - December
>
2001-12-10
>
06-J Cox Field Water Main
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/12/2012 11:03:47 AM
Creation date
12/4/2001 10:38:47 PM
Metadata
Fields
Template:
AGENDA
Item Number
6-J
AGENDA - Type
RESOLUTION
Description
Award bid for replacement of 8" water main at Cox Field Airport
AGENDA - Date
12/10/2001
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
206
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2005.01 <br />The work to be <br />equipment and material and <br />embedment, encasement, and <br />2005.02 GENERAL <br />All water lines shall be <br />Water Systems", Adopted 1978 by tt <br />(f), Water Distribution - Location of : <br />293305(2), or latest edition thereof. <br />2005.03 EXCAVATION <br />(a) General <br />Excavation shall <br />that may obstruct the line of work, <br />the extent necessary to install the p <br />the plans, and as specified. <br />(b) <br />The sides of all trench <br />on the p]ans, the minimum width of ~ <br />(12) inches plus the outside diameter <br />(24) inches plus the outside diameter <br />inches above the top of the pipe whc <br />Wherever the pc <br />class embedment or encasement <br />width as actually cut, and the ai <br />:d under this specification shall consist of fumishing all labor, <br />all work necessary, in connection with excavating, trenching, <br />for the installation of sanitary sewer and water line pipelines. <br />installed in accordance with the "Rules and Regulations for Public <br />Texas Department of Health, Revised 1988, Section 337.206 (d) & <br />ains, and in accordance with 31 Texas Administrative Code, Section <br />e the removal of any trees, stumps, brush, debris, or other obstacles <br />d the excavation and removal of all earth, rock, or other ma[erials to <br />and appurtenances in conformance with the line and grades shown in <br />shall be cut as nearly vertical as possible. Unless otherwise specified <br />nch in which the pipe may be installed shall not be less than twelve <br />the pipe, and the mauimum width shall not be more than twenty-four <br />'the pipe, measured at an elevation in the trench which is twelve (12) <br />it is laid to grade. <br />maximum trench width is exceeded, the Contractor shall use the <br />by the Engineer to provide the load carrying capacity for the trench <br />cost incurred will be bome by the Contractor. <br />(c) Shoiiniz and Jheetlilg <br />The need for sheetin~and shoring, and the method and equipment used to sheet and shore <br />shall be in compliance with the Tren Safety System developed to conform with the Trench Safety System <br />Specification, Item 2100, and to comply with existing laws. It shall be the fiall and sole responsibility of the <br />Contractor to provide a safe working environment. <br />Item 2005-1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.