15.1 Minimutn Mechanical Systems Standatds <br />A. Each dwelling and/or dwelling unit must be supplied with its own beatiag system• <br />g. All heating facilities must be propecly installod, bo maintained in working condition aad be <br />capable of adequately heating all habitable rooms, bathroams, and toilet rooms contained therein, <br />or intended for use by the occupants thereof, to a temperaturo of at least 70 dagas F. (21 -degcees <br />C. ) at a distancc 3 feet above the floor when the outside tempetsture is at or below rninus 10 <br />degt+ces F. <br />C. Ambient heat must be supplied from an.adequate heat source in an adjoining room or hallway; <br />D. Every supplied central heating system must comply with all of the following requirements: <br />E. The central heatiag ut►it must be safe and in good working condition. <br />F. Every heat duct, steam pipe, and hot water pipe muat be free of leaks and must function so that an <br />adequate smount of heat is detivered where intanded; <br />G. Every seal between anY of the sections of a hot air furnace must be air-tight so noxious gases and <br />fumes will not escape into the heat ducts; liner must be installed• The liner must meet or exceod <br />the requirements of the (ocal buildinp,lheating code and must be installed according W same• <br />Where there are no local buiiding/headng codos, equipmont and installation must be inspected and <br />approved by a person qualified in this area as designated by the city/county/state <br />H. Whencver an existing structure has as its sow+ce of central heat the old ocWpus rype conversion <br />fumace, the unit must be inspectod by a qualified furnace inspector to determine if the unit is still <br />safe, free from carbon-monoxidc leakage and capable of supplying heat as reQuired above. <br />I. Every supplied space hester must comply with all of the following requiroments: <br />1. No space heater burning solid, Liquid, or gaseous fuels must be of a poctable type; <br />K. Every space heater burning solid, liyuid, or gascous fuels must be properly vented to a ohimney or <br />duct leading to outdoor space and must be so installed as to provide proper draft (except when a <br />functioning ODS system and a CO testing device is installcd). <br />L Every fuel burning space heater mnst have a fire-resistant panel between it and the floor or floor <br />coveriag; whenever a space heater is locatad within 2 feet of a wall, said wall must be protectod <br />with insulation aufficient to prevent overheating of the wall. <br />M. Every space heater smoke pipe must be oi a~ ub~le flsmmabl~ material! with <br />approved type thimbles or guards, PropeT Y <br />whece the pipe goes thrnugh any wall, ceiling, or partition the pipe muat bc surrounded by a <br />protective collar or escutcheon. <br />N. Whenever feasible, un-vented free standin8 sPace heaters ghould bc removed and replaced with <br />vented types. In rare situations, whtn vented rype units are not feasble, un-vented ODS equipped <br />units may be installed if appmved by the City, County and State. In cases when ODS oquipped <br />heaw are used a Carbon Moaoxide testiag device will be permatietulY installed. <br />p. All Texas, "T" walves should be replaced with approved shut off vaives. <br />Page 19 of <br />TDHCA- Home Inveshnent Parhnerships Program <br />23 Revised O1/01/2004 <br />qppendix A-03 - TMC Stendards ~ 254 <br />