Laserfiche WebLink
Phase II - Scope of Work - Asbestos Abatement Irerracon <br />Grand Theatreâ–  21 Lamar Avenue, Paris, Texas <br />June 4, 2012 â– Terracon Project No. 94107645 <br />p) CONTRACTOR will include the cost of the TDSHS notification fee in their base <br />bid. <br />q) AIA Contract A-101 2007 will be used for this project as the contract with the <br />owner. Supplementary Condition to the Standard Form of Agreement Between <br />Owner and CONTRACTOR. <br />3.0 WORK PRACTICES <br />3.1 Respiratory Protection <br />Throughout the project, respirators shall be provided by the CONTRACTOR. The <br />CONTRACTOR will provide respirators which are applicable and suitable for the <br />purpose intended in accordance with OSHA 1910.134 - Respirator Standard. The <br />CONTRACTOR will ensure that the respirators are equipped with filter cartridges <br />designed for asbestos-containing dusts and mists, vapors, and color-coded in <br />accordance with ANSI Z228.2 (1980). <br />3.2 Protective Clothing <br />During removal of the ACM, at least one protective suit will be worn by each worker. <br />Boots and gloves will be made available to each worker as needed. All protective suits <br />will be properly disposed of at the conclusion of the work. The workers performing the <br />abatement will decontaminate thoroughly in three-chambered wet decontamination <br />system attached to each containment. <br />3.3 Containment <br />The asbestos containing materials will be abated in a full containment constructed of two <br />(2) layers of 4-mil polyethylene sheeting on the walls and two (2) layers of 6-mil <br />polyethylene sheeting on the floors (where applicable), and one layer of 4-mil <br />polyethylene sheeting on the ceiling, in conjunction with critical barriers, negative <br />pressure, and a three chambered wet decontamination system. <br />Decontamination System: disposable/pop-up units displaying excessive use or <br />wear will not be permitted for the decontamination system. Provide a Personnel <br />Decontamination Unit consisting of a serial arrangement of connected rooms or spaces, <br />Changing Room, Shower Room, and Equipment Room. Require all persons without <br />exception to pass through this decontamination unit for entry into and exiting from the <br />work area for any purpose. Do not allow parallel routes for entry or exit. / <br />Chanqinq Room (clean room): Provide a room that is physically and vAsyfally/separated <br />rcye rrougns <br />TDSHS ice e # 0-5095 <br />13 <br />