My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
14-MOVE TO APPROVE RES ACCEPTING BID AND AWARDING CONTRACT FOR SECOND PHASE OF HAZARDOUS MATERIALS REMEDIATION OF GRAND THEATER TO NCM DEMOLITION AND REMEDIATION LP
City-of-Paris
>
City Council
>
Agenda Packets
>
2011-2020
>
2012
>
06 June
>
06.25.12
>
14-MOVE TO APPROVE RES ACCEPTING BID AND AWARDING CONTRACT FOR SECOND PHASE OF HAZARDOUS MATERIALS REMEDIATION OF GRAND THEATER TO NCM DEMOLITION AND REMEDIATION LP
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2012 10:59:46 AM
Creation date
6/20/2012 10:49:50 AM
Metadata
Fields
Template:
CITY CLERK
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
87
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Phase II - Scope of Work - Asbestos Abatement Irerracon <br />Grand Theatreâ– 21 Lamar Avenue, Paris, Texas <br />June 4, 2012 â– Terracon Project No. 94107645 <br />that protect the balance of the building or outside of the building from contamination by <br />airborne fibers. <br />AIRBORNE FIBER COUNTS: <br />Inside Work Area: Maintain an average airborne count in the Work Area of less than 0.1 <br />fibers per cubic centimeter. If the fiber counts rise above this figure for any sample <br />taken, revise work procedures to lower fiber counts. If the Time Weighted Average <br />(l1NA) fiber count for any Work shift or eight (8) hour period exceeds 0.1 fibers per cubic <br />centimeter, stop work and leave ventilation system in operation. Do not recommence <br />work until authorized by the CONSULTANT. <br />Outside Work Area: Maintain an average airborne count outside the Work Area below <br />the Permissible Exposure Limit (PEL) of 0.1 f/cc of air. <br />If any air sample taken outside the Work Area exceeds the PEL, immediately stop work <br />until the source of the elevated fiber readings can be determined by the CONSULTANT. <br />Immediately take corrective as instructed by the CONSULTANT. <br />Decontaminate the affected area in accordance industry standard methods. <br />ANALYTICAL METHODS: <br />The following methods will be utilized at the discretion of the CONSULTANT in collecting <br />and analyzing air samples: <br />Phase Contrast Microscopy (NIOSH 7400 Method, Issue 2, Revision 3 or OSHA <br />Reference Method) <br />SAMPLE PROTOCOLS: <br />General: The number and volume of air samples taken by the CONSULTANT will <br />generally be in accordance with the following schedule. Sample quantities, locations, <br />volumes and methodologies may vary depending upon the analytical method, project <br />layout, procedures used and at the discretion of the CONSULTANT. <br />SCHEDULE OF AIR SAMPLES FOR CONTAINMENT(S): <br />Daily Sample Schedule (per 8-hour work period): The CONSULTANT will generally take <br />the following samples on a daily (8-hour work period) basis. The number of samples <br />may vary according to site plan and on authorization of CONSULTANT. <br />K le rroughs <br />TDSHS Li e e# 0-5095 <br />Expiration Date: 02.09.13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.