My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
06 A to F-Depot Project Manual
City-of-Paris
>
City Council
>
Agenda Packets
>
2001-2010
>
2001
>
09 - September
>
September 10, 2001
>
06 A to F-Depot Project Manual
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2005 11:22:54 AM
Creation date
8/2/2001 8:16:15 PM
Metadata
Fields
Template:
AGENDA
Item Number
6-A through 6-F
AGENDA - Type
PROJECT MANUAL
Description
Paris Santa Fe-Frisco Railroad Depot Rehabilitatio
AGENDA - Date
9/10/2001
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
353
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Paris Santa Fe-Frisco Depot Rehabilitation © K[YSTON[ ARCHIT[CT$ <br /> July 10, 2001 <br /> <br /> used. All corrective treatments shailbe performed to at least 10 feet <br /> around each visible termite activity. <br /> <br /> a. Working pressure while applying treating solution shall be held to that which <br /> is applicable to and safe under the conditions at the sitebeing <br /> treated. <br /> <br /> b. Drill and treat at a rate consistent with the pesticide label. <br /> <br /> c. Treat through ail floors, aiong both sides of ail partitions and wails, and all <br /> cracks and expansion joints according to label directions. Do not <br /> harm, alter or drill through existing materials. <br /> <br /> d. Drill one hole at each plumbing or utility penetration through ground floor <br /> slab and treat according to label instructions. <br /> <br /> e. Reinstall carpets as applicable/necessary. Installation shall be done by a <br /> competent commerciai caxpet installer. <br /> <br /> f. Replace any finish/finish materiais which are contaminated by spilled <br /> chemicais. <br /> <br /> 5. The above-ground areas infested with subterranean termites shail be treated as <br /> appropriate with a proven, effective insecticide to eliminate those termites. <br /> <br />PART 2 - PRODUCTS <br /> <br />2.01 MATERIALS <br /> A. Asbestos Prohibition: Only EPA approved materials shall be used. The Contractor <br /> shail insure that all materiais incorporated in the project are EPA approved. <br /> <br /> B. Chemicals shall be aqueous solutions of Dursban TC, Torpedo, Dragnet, Demon TC or <br /> Prevail FT and shall be used in accordance with the labels and provisions related to <br /> the use of those pesticides as adopted by the State of Texas and the Federal Insecticide, <br /> Fungicide and Rodenticide Act. <br /> <br />PART 3 - EXECUTION <br /> <br />3.01 APPLICATION AND RATES <br /> A. Whenever possible, the solution shail be applied not more than 24 hours before the <br /> pouring of concrete over affected areas. <br /> <br /> B. The treatment shall be applied to dry materiai whenever possible, but in any case <br /> shall not be applied under conditions during which the soil does not readily absorb the <br /> solution. <br /> <br /> C. The solution shall be applied uniformly and at the rates indicated on the label for the <br /> chemicai being used. <br /> <br /> * * END OF SECTION * * <br /> <br /> Section 02281 <br /> Page 2-2 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.