My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
05-D Animal Shelter Contract
City-of-Paris
>
City Council
>
Agenda Packets
>
2001-2010
>
2002
>
08 - August
>
2002-08-12
>
05-D Animal Shelter Contract
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/12/2012 9:30:22 AM
Creation date
8/9/2002 9:03:58 PM
Metadata
Fields
Template:
AGENDA
Item Number
5-D
AGENDA - Type
RESOLUTION
Description
Award the bid and authorize the contract for the construction of the City of Paris Animal Shelter
AGENDA - Date
8/12/2002
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
177
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
nxvisxox 15-s <br />HEATING AND A/C <br />ELECTRICAi. WORx: The following work will be approved <br />under Division 16 of the specification: Electrical <br />services from panel to each motor. Make proper connection <br />to all motors and motor controllers as furnished under <br />this Division of specification. Install all manual and <br />interlock control work. Install all conduit and wiring <br />for control system under the direction of the A/C <br />contractor who will furnish thermostats. Provide service <br />and make proper connection to electric heat and controls. <br />Provide service and control switches for exhaust fans. <br />MOTORS AND MOTOR CONTROLLERS⢠Furnish, for installation <br />by the Electrician, a motor and motor controller for the <br />operations of each piece of equipment. Exhaust fan and <br />motorized damper. Motors shall be G.E., Century, or <br />approved equal with open frame, unless otherwise required. <br />Motor controls shall be G.E., Cutler-Hammer, Allen <br />Bradley, or approved equal. Verify electric service <br />characteristics prior to furnishing motors and <br />controllers. Furnish manual controllers for all such <br />motors. <br />Wall type fan switches shall, when turned on, turn on <br />exhaust fans and activate motorized dampers to open <br />completely the outside air louvers at intake openings. <br />When turned to the off position, the exhaust fans shall <br />turn off and the motorized damper shall be activated to <br />close the fresh air system to the outside air. <br />CONTROL 9YSTEM: Eurnish for installation by the <br />Electrician winter, summer, and auto change over, <br />thermostats, and switches for change from heating to <br />cooling, and fan continuos switch. Thermostats shall be <br />Honeywell, or approved equal, of type required for the <br />operation of heating, cooling, or fan only. It will be <br />the responsibility of the Electrician to install wiring <br />and make all connections for controls. It will be the <br />responsibility of this Contractor to direct such work and <br />give proper notice of any changes required. <br />' AIR CONDITIONING EQUIPMENT SCHEDULE⢠Is shown in detail <br />on plan. Trade names where shown are intended to <br />designate the quality of equipment desired. Equipment of <br />other manufacturer may be used when approved by the <br />Architect. <br />17 lr% <br />
The URL can be used to link to this page
Your browser does not support the video tag.