My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1979-1996
City-of-Paris
>
Boards and Commissions
>
BUILDING AND STANDARDS COMMISSION
>
1979-2009
>
1979-1996
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/9/2015 2:27:24 PM
Creation date
2/10/2015 4:07:46 PM
Metadata
Fields
Template:
CITY CLERK
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
175
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(1f) Paragraph 19.4.5 shall be deleted. <br />(18) Paragraph 19.4.9 shall be <br />or Device and Minimum Pipe Size <br />the following: <br />"!-later Heater. <br />changed by adding under Type of Fixture <br />and immediately after !gall Hydrant 2, <br />3/4" <br />(19) Paragraph 19.4.12 shall.be changed to read as follows: <br />"19.4.12 Water Supply Control: An approved stop and waste shut -off <br />valve shall be installed in the water service pipe on the property side <br />of the meter, adjacent to the City Meter Box. Said va tve. shall be enclosed <br />in:� plastic valve box with a removable cover equipped with �Icut off key. <br />There shall be a six (6) foot minimum seperation of the valve from any <br />sewer clean out plug. <br />(20) Paragraph 22.2.1 Change first sentence to read "All pipe used for <br />the installation, extension, alternation, or repair of any gas piping <br />small be new, standard - weight black steel, ployethylene or tin lined <br />copper, free from splits, internal obstruction or other defects. <br />(21) Paragraph 22.2.2 The second sentence is changed to read as follows: <br />"Polyethylene tubing shall be manufactured i.n.accordance aiith requirements <br />for PE 2306 or equivalent tubing in specifications for Plastic.0as Pressure; <br />Tubing, Pipe and Fittings. ASTM Designation D- 2513766T. The last sentence <br />is changed to read as follows: This material shall be connected together <br />by use of flared fittings or compression fittings and screwed connections <br />and be installed in accordance with manufacturer's recomm.endations.- <br />The following sentence shall.be added: "Polyethylene pipe shall not be <br />flared, threaded or extended above ground level." <br />(22) Paragraph 22.2.3 The first sentence is changed to read as follows: <br />"Service lines underground shall be polyethylene pipe and fittings conforminn <br />to A.S.T.M. D- 2513 -57 and C.S. 255 -63 or black steel protected against <br />soil corrosion with an approved type protective coating and sacrificial w <br />anode and shall be installed according to manufacturer's recommendations. <br />The following shall be added: Polyethylene pipe shall be installed with <br />an electrically conductive tracer wire and shall not extended above around <br />level.Customer portion of underground service pipe connected to high pressure <br />gas shall not be less than 3/4 inch in size and those connected to low pressure <br />gas shall not be less th4n 1 -1/4 inch in sizes provided size is sufficient <br />for capacity requirements. Metal casing may be used in lieu of tracer wire.,. <br />(23) Paragraph 22.2.4 Add third sentence: Polyethylene pipe 3/4 inch and <br />larger may be connected to the same grade and specification material by an <br />approved heat fusion method. <br />(24) Paragraph 22.2.5 Sentence two and three shall be changed to read as follows: <br />"Fittings 3 inches and smaller shall be of black malleable iron but cast -iron <br />fittings may be used in sizes above 3 inches. An approved type plug valve shall <br />be installed in the meter loop on the street side or at the house riser <br />where the meter is located at the curb or property line. <br />
The URL can be used to link to this page
Your browser does not support the video tag.